It’ll run for about a minute then shut off
I plug it in and it’ll run fine . Both fans and compressor are running and in about a minute it’ll shut down like I unplugged iy
crwdns2933947:0crwdne2933947:0
crwdns2930901:0crwdne2930901:0crwdns2933953:020crwdne2933953:0
crwdns2916016:0crwdne2916016:0
crwdns2933933:01crwdne2933933:0
crwdns2931729:0crwdne2931729:0:
I plug it in and it’ll run fine . Both fans and compressor are running and in about a minute it’ll shut down like I unplugged iy
crwdns2933933:0505,8crwdns2936485:0crwdne2936485:0crwdne2933933:0
crwdns2931729:0crwdne2931729:0:
Hi @kevinmcpike,
Does the light in the compartment still work when this occurs?
It seems like it may be a faulty Overload and PTC start relay - part #13 Unit parts diagram, part #WP2154697 (supplier example only) and hopefully it is not a faulty compressor.
Ideally to test this you would need an AC clamp meter to measure the compressor current draw when it is starting/running and check if it is within the specifications.
It is in within specs then it may be a faulty PTC relay. Search online for the part number to find suppliers that suit you best.
Unfortunately looking at images online of the compressor part #W10309994 there doesn't seem to be any amp load rating specifications shown on the label. Check the label anyway just in case it is on your compressor.
If you have a DMM (digital multimeter) you could do a static test i.e. no power connected to the freezer and check if the compressor windings are OK. Here's a video that may help with this.
If it is the compressor, then depending on your location, you may need to use a licensed repairer to replace it due to the environmental regulations regarding the handling of refrigerant gases