Whirlpool Dryer Motor Testing and Replacement, Test the start winding: crwdns2935265:00crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 Whirlpool Dryer Motor Testing and Replacement, Test the start winding: crwdns2935265:00crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 Whirlpool Dryer Motor Testing and Replacement, Test the start winding: crwdns2935265:00crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
Test the start winding
  • This step will require a multimeter. If you aren't familiar with how to use one, here is a guide that will help you.

  • Disconnect the wire that is connected to the start winding that you located on the schematic. On this machine, it is aligned with terminal 3.

  • Measure the resistance from the start winding wire to the common terminal shared between the start and run windings. Use the lowest resistance setting (usually Rx1) on your multimeter if you need to set it manually.

  • The value should be 2–5 Ω. If it's outside that range or OL, the motor is defective and needs to be replaced.

这一步需要使用万用表。如果您不熟悉如何使用万用表,这里有一份指南会对您有所帮助。

断开与原理图上的启动绕组相连的导线。在本机器上,它与端子 3 对齐。

测量启动绕组导线到启动绕组和运行绕组共用的公共端子之间的电阻。如果需要手动设置,请使用万用表的最低电阻设置(通常为 Rx1)。

如果超出该范围或为 OL,则电机有故障,需要更换。