How to Fix the C6 Error for a Pressure Cooker

crwdns2936315:0crwdne2936315:0
crwdns2936323:0crwdne2936323:0
crwdns2931653:07crwdne2931653:0
How to Fix the C6 Error for a Pressure Cooker, Diagnose the C6L error: crwdns2935265:00crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 How to Fix the C6 Error for a Pressure Cooker, Diagnose the C6L error: crwdns2935265:00crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 How to Fix the C6 Error for a Pressure Cooker, Diagnose the C6L error: crwdns2935265:00crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
Diagnose the C6L error
  • This step shows how to test the low pressure sensor more extensively. You should check this sensor if you get a C6L error.

  • Disconnect the low pressure sensor by squeezing its circuit board connector to disengage the lock, then pull straight up.

  • Attach a multimeter lead to both exposed ends of the sensor wires, making sure the leads don't touch each other.

  • Set the meter to resistance/continuity and test for continuity, when the sensor is resting, and when it's depressed.

  • The meter should show low resistance/continuous when the sensor is resting, and no continuity when the sensor's depressed.