How to Fix the C6 Error for a Pressure Cooker

crwdns2936315:0crwdne2936315:0
crwdns2936323:0crwdne2936323:0
crwdns2931653:06crwdne2931653:0
  • In its resting state, the pressure sensor should be continuous, which means the meter should read almost zero resistance.

  • If the meter shows a high resistance or no continuity, it could mean that the sensor contacts are dirty. Double-check your meter contacts and make sure they're grasping onto the wires.

  • Use a spudger or your finger to firmly press on the top of the sensor until it clicks.

  • The meter should change to show no continuity (0.L, in my meter's case). If it doesn't, there is a potential electrical short—the contacts may be fused, or you may need to replace the sensor.