Compressor will not run
You've tried everything... No matter what you do, you can't get your compressor to turn on.
Switch is in OFF position
As obvious as this suggestion may be... just check the On/Off switch. It should be in the ON position.
No electricity at the wall socket
Check the circuit breaker and fuse corresponding to the outlet you are using. Make sure the circuit breaker has not been tripped or a fuse blown.
Compressor has reached automatic shutoff pressure
This model is designed to automatically shut off the pump motor at a designated pressure. Try Releasing air in order to reduce the pressure and allow the motor to turn on to rebuild tank pressure.
Motorized pump has overheated
The thermal overload switch may be triggered. Allow the compressor to cool in open area for at least 30 minutes. Try not to run the motor in excess of 100 degrees Fahrenheit.
Faulty Pressure Switch
Replace the pressure switch. See the replacement guide for step-by-step instruction.
Tank pressure drops when air compressor shuts off
If your tank pressure does not hold when the compressor motor turns off, the tank has some kind of leaky component.
Loose Drain Valve
If the drain valve is loose, tighten the valve. Check the connections between hoses and fittings with soapy water to detect possible leaks after tightening.
Leaky Check Valve
If the check valve is leaking, replace with a new check valve. See the replacement guide for step-by-step instructions. Check the connections between the hoses and fittings with soapy water to detect possible leaks after replacing the valve.
Compressor Runs Continuously and Low Air Discharge Output
The compressor is designed to shut off at a specific pressure inside the tank. Basically, the compressor is unable to accumulate enough pressure to properly function.
Compressor may be too small to accomplish task
See user manual for the pressure rating and the compressor limitations.
Loose connections (fittings, tubing, etc.)
Check the connections between the hoses and fittings with soapy water to detect possible leaks.
Broken inlet valves / Piston ring worn out
Replace entire pump assembly.
Compressor runs continuously and safety valve opens as pressure rises
The continuous accumulation of pressure will eventually discharge through the safety valve if the pressure levels reach the critical pressure threshold for this compressor.
Defective Pressure Switch
Replace the pressure switch with a new component.
Defective safety valve
Replace safety valve with a genuine replacement component. This is critical because if you do not use the correctly manufactured valve, pressure can exceed expected limits and become potentially hazardous to the user.
Excessive starting and stopping
"Common causes for excessive or random starting and stopping can be attributed to lack of regular maintenance of the compressor.''
Condensation accumulated in compressor tank
Drain the tank more regularly.
Loose connections(fittings, tubing, etc)
Check the connections between the hoses and fittings with soapy water to detect any possible leaks
Replacement Parts
If you come across an issue not mentioned in this troubleshooting page or need to purchase replacement parts for your machine, visit eReplacementParts.com
crwdns2944067:06crwdne2944067:0
I have a ch oiless air compressor 5.5 hp 30 gallon tank. when it is below 30 degrees the compressor pumps only about 50 pounds . above 30 the compressor work s fine . is this a deal with this type of compressor not cold blooded. I keep it in my garage and it gets cold in iowa.
let me know what you guys think thanks
marv
marvbailey - crwdns2934203:0crwdne2934203:0
My compressor reach 65 pis and shut off then I have to wait 10 minutes before it starts again. What could be the problem please answer back thanks
Wilson Figueroa - crwdns2934203:0crwdne2934203:0
When I start up my compressor, the oil cap blows off and oil gushes out
carrolleaket - crwdns2934203:0crwdne2934203:0
To much compression for the motor to rotate the wheel
parkeandjackie1401 - crwdns2934203:0crwdne2934203:0
I have a model FP209501 and the compressor won’t turn on at all. It’s done this once before when I had it in my garage but I got it to turn on. Now it’s not doing nothing. Any help would be appreciated. Thanks!
Michael Hood - crwdns2934203:0crwdne2934203:0
I have an air compressor model WL600602AJ, 11 gallon capacity. When started, after running for about 4 minutes, it trip the breaker. Try to make adjustment on pressure switch but nothing happened. Tha pressure is building up but not stopping automatically. What could the the trouble? Any idea?
vioczar - crwdns2934203:0crwdne2934203:0