crwdns2933423:0crwdne2933423:0

如何使用万用表

crwdns2936315:0crwdne2936315:0
crwdns2936311:0crwdne2936311:0
crwdns2931653:012crwdne2931653:0
How To Use A Multimeter, Manual ranging voltage measurement: crwdns2935265:00crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 How To Use A Multimeter, Manual ranging voltage measurement: crwdns2935265:00crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 How To Use A Multimeter, Manual ranging voltage measurement: crwdns2935265:00crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
Manual ranging voltage measurement
  • Follow this step to measure voltage with a manual ranging multimeter.

  • Place the red probe on the positive terminal, and the black probe on the negative terminal.

  • If your range was set too high, you may not get a very precise reading. Here the multimeter reads 9 volts. That's fine, but we can turn the dial to a lower range to get a more precise.

  • If you set the range too low, the multimeter simply reads 1 or OL, indicating that it is overloaded or out of range. This won't hurt the multimeter, but we need to set the dial to a higher range.

  • With the range set correctly, we get a reading of 9.42 volts.

  • Reversing the probes won't do any harm; it just gives us a negative reading.

按照此步骤使用手动量程万用表测量电压。

将红色探针放在正极端子上,将黑色探针放在负极端子上。

如果量程设置得过高,可能无法获得非常精确的读数。这里万用表的读数是 9 伏。这很好,但我们可以将表盘转到较低的量程,以获得更精确的读数。

如果量程设置得过低,万用表只会读出 1 或 OL,表明其已超负荷或超出量程。这不会损坏万用表,但我们需要将刻度盘调到更高的量程。

正确设置范围后,我们得到的读数为 9.42 伏。

反转探头不会造成任何伤害;它只会给我们一个负的读数。