crwdns2933423:0crwdne2933423:0

惠而浦干衣机出口热敏电阻测试和更换

crwdns2936315:0crwdne2936315:0
crwdns2936311:0crwdne2936311:0
crwdns2931653:03crwdne2931653:0
Whirlpool Dryer Outlet Thermistor Testing and Replacement, Testing the outlet thermistor: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
Testing the outlet thermistor
  • If you aren't sure how to use a multimeter, take a look at this guide.

  • Set your multimeter to the ohms (Ω) setting. If your meter has more than one scale for ohms (Ω), set it to (Rx1000).

  • Touch the probes to the contacts on the thermistor. The reading at room temperature (70°F/21°C) should be about 12.5–14.5 kΩ for a Whirlpool Duet dryer;

  • Other models may have different values; 10 kΩ is common at room temperature (70°F/21°C) for another outlet thermistor (also called temperature control thermistor).

  • If your thermistor reads outside the proper range or reads no continuity (OL) or 0.00 Ω, follow the next steps to replace it.

如果您不确定如何使用万用表,请参阅 本指南

将万用表调至欧姆 (Ω) 档。如果您的万用表有多个欧姆 (Ω) 刻度,请将其设置为 (Rx1000)。

将探针接触热敏电阻的触点。对于惠而浦 Duet 烘干机,室温(70°F/21°C)下的读数应约为 12.5-14.5 kΩ;

其他型号可能有不同的值;室温(70°F/21°C)下,另一个出口热敏电阻(也称为温度控制热敏电阻)的常用值为 10 kΩ。

如果热敏电阻的读数超出正常范围或读数不连续 (OL) 或为 0.00 Ω,请按照以下步骤进行更换。