crwdns2933423:0crwdne2933423:0

Test e sostituzione termistore di uscita asciugatrice Whirlpool

crwdns2936315:0crwdne2936315:0
crwdns2936321:0crwdne2936321:0
crwdns2931653:03crwdne2931653:0
Whirlpool Dryer Outlet Thermistor Testing and Replacement, Testing the outlet thermistor: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
Testing the outlet thermistor
  • If you aren't sure how to use a multimeter, take a look at this guide.

  • Set your multimeter to the ohms (Ω) setting. If your meter has more than one scale for ohms (Ω), set it to (Rx1000).

  • Touch the probes to the contacts on the thermistor. The reading at room temperature (70°F/21°C) should be about 12.5–14.5 kΩ for a Whirlpool Duet dryer;

  • Other models may have different values; 10 kΩ is common at room temperature (70°F/21°C) for another outlet thermistor (also called temperature control thermistor).

  • If your thermistor reads outside the proper range or reads no continuity (OL) or 0.00 Ω, follow the next steps to replace it.

Se non sei sicuro di come usare un multimetro, dai un'occhiata a questa guida.

Imposta il tuo multimetro sulla scala degli ohm (Ω). Se il tuo strumento ha più di una scala per gli ohm (Ω), impostalo su (Rx1000).

Tocca i contatti del termistore con le sonde. La lettura a temperatura ambiente (21°C) dovrebbe essere di circa 12,5-14,5 kΩ per un'asciugatrice Whirlpool Duet .

Altri modelli possono avere valori diversi; 10 kΩ è un valore comune a temperatura ambiente (21°C) per un altro termistore di uscita (chiamato anche termistore di controllo della temperatura).

Se il termistore non rientra nell'intervallo corretto o non mostra continuità (OL) o 0,00 Ω, segui i passi successivi per sostituirlo.

crwdns2944171:0crwdnd2944171:0crwdnd2944171:0crwdnd2944171:0crwdne2944171:0