Whirlpool Dryer Outlet Thermistor Testing and Replacement, Testing the outlet thermistor: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
Testing the outlet thermistor
  • If you aren't sure how to use a multimeter, take a look at this guide.

  • Set your multimeter to the ohms (Ω) setting. If your meter has more than one scale for ohms (Ω), set it to (Rx1000).

  • Touch the probes to the contacts on the thermistor. The reading at room temperature (70°F/21°C) should be about 12.5–14.5 kΩ for a Whirlpool Duet dryer;

  • Other models may have different values; 10 kΩ is common at room temperature (70°F/21°C) for another outlet thermistor (also called temperature control thermistor).

  • If your thermistor reads outside the proper range or reads no continuity (OL) or 0.00 Ω, follow the next steps to replace it.

Si no estás seguro de Cómo usar un multímetro, echa un vistazo a esta guía.

Pon tu multímetro en el ajuste de ohmios (Ω). Si tu multímetro tiene más de una escala para ohmios (Ω), ponla en (Rx1000).

Toca con las sondas los contactos del termistor. La lectura a temperatura ambiente (70 °F/21 °C) debe ser de unos 12,5-14,5 kΩ para una secadora Whirlpool Duet;

Otros modelos pueden tener valores diferentes; 10 kΩ es común a temperatura ambiente (70°F/21°C) para otro termistor de salida (también llamado termistor de control de temperatura).

Si tu termistor lee fuera del rango adecuado o lee sin continuidad (OL) o 0,00 Ω, sigue los pasos siguientes para reemplazarlo.