How to Fix a Solder Bridge: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
  • Verify the circuit board does not have any current supplied to it prior to performing the next steps. If a current is present, permanent damage to the multimeter is possible!

  • Connect the black probe to the circuit board rail where one end of the solder bridge was.

  • Connect the red probe to the circuit board rail where the other end of the solder bridge was.

  • If the fix is successful, the multimeter should read "OL" on the screen, indicating an open circuit. There should be no beep, which means the rails are no longer connected.

  • If the fix was unsuccessful, the multimeter will give a numerical readout on the multimeter screen, and beep.

Bevor du die nächsten Schritte ausführst, musst du dir ganz sicher sein, dass die Platine nicht an eine Stromquelle angeschlossen ist. Wenn eine Spannung anliegt, kann das dein Multimeter nachhaltig schädigen!

Halte das schwarze Testkabel an diejenige Leiterbahn auf der Platine, an der sich das eine Ende der Lötbrücke befand.

Halte das rote Testkabel an diejenige Leiterbahn auf der Platine, an der sich das andere Ende der Lötbrücke befand.

Wenn die Reparatur geklappt hat, sollte das Multimeter jetzt "OL" auf dem Display anzeigen. Das Gerät sollte nicht piepen, das bedeutet, dass die Leiterbahnen nicht mehr in Verbindung sind.

Wenn die Reparatur nicht geklappt hat, zeigt das Multimeter eine Zahl auf dem Display an und piept.