Whirlpool WED87HED Dryer Hi-Limit Thermostat/Inlet Thermistor Testing and Replacement, Test the inlet thermistor: crwdns2935265:00crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Whirlpool WED87HED Dryer Hi-Limit Thermostat/Inlet Thermistor Testing and Replacement, Test the inlet thermistor: crwdns2935265:00crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
Test the inlet thermistor
  • This step shows how to test the inlet thermistor. If you just need to replace the hi-limit thermostat or inlet thermistor, you can skip this step.

  • With the thermistor removed from the heater housing, test for resistance with the multimeter across the two small terminals.

  • The value shown (61.8 kΩ) is acceptable for a good thermistor at room temperature (68°F/20°C). The nominal range at this temperature is 61.2‑63.7 kΩ.

  • If the device shows outside this range, replace it.

Este paso muestra cómo comprobar el termistor de entrada. Si sólo tienes que reemplazar el termostato de alto límite o el termistor de entrada, puedes saltarte este paso.

Con el termistor desmontado de la carcasa del calentador, comprueba la resistencia con el multímetro a través de los dos terminales pequeños.

El valor indicado (61,8 kΩ) es aceptable para un buen termistor a temperatura ambiente (68°F/20°C). El rango nominal a esta temperatura es de 61,2-63,7 kΩ.

Si el dispositivo muestra un valor fuera de este rango, sustitúyelo.