crwdns2933423:0crwdne2933423:0

Continuïteit van een netsnoer testen

crwdns2936315:0crwdne2936315:0
crwdns2936313:0crwdne2936313:0
crwdns2931653:02crwdne2931653:0
Testing Power Cord Continuity, Test for a break in the cable: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
Test for a break in the cable
  • Test for a potential open circuit by using one multimeter lead to touch one of the prongs on the AC side of power cord. Use the other lead to touch one end of the console side of the power cord.

  • If there is an adequate electrical connection, the multimeter will continuously beep. A short beep does not mean that there is continuity. If it does not beep the first time, try using the lead to touch the other prong.

  • Repeat the above directions in step 2 for the other outlet and prong of the power cord.

  • If the multimeter fails to beep on any of the occasions outlined above, your power cord is open. In other words, you will need to replace the power cable.

Test op een mogelijk open circuit door één multimeterdraad te gebruiken om een van de pennen van het netsnoer aan te raken. Gebruik de andere multimeterdraad om een aansluiting aan het andere uiteinde van het netsnoer aan te raken.

Als er een adequate elektrische verbinding is, zal de multimeter continu piepen. Een korte piep betekent niet dat er continuïteit is. Als het de eerste keer niet piept, probeer dan de draad te gebruiken om de andere pin aan te raken.

Herhaal de bovenstaande aanwijzingen in stap 2 voor de andere pen en het andere uiteinde van het netsnoer.

Als de multimeter op geen van de hierboven beschreven momenten piept, is uw netsnoer onderbroken. Met andere woorden, u moet het netsnoer vervangen.

crwdns2944171:0crwdnd2944171:0crwdnd2944171:0crwdnd2944171:0crwdne2944171:0