crwdns2933423:0crwdne2933423:0

Wie man ein Stromkabel prüft

crwdns2936315:0crwdne2936315:0
crwdns2936319:0crwdne2936319:0
crwdns2931653:02crwdne2931653:0
Testing Power Cord Continuity, Test for a break in the cable: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
Test for a break in the cable
  • Test for a potential open circuit by using one multimeter lead to touch one of the prongs on the AC side of power cord. Use the other lead to touch one end of the console side of the power cord.

  • If there is an adequate electrical connection, the multimeter will continuously beep. A short beep does not mean that there is continuity. If it does not beep the first time, try using the lead to touch the other prong.

  • Repeat the above directions in step 2 for the other outlet and prong of the power cord.

  • If the multimeter fails to beep on any of the occasions outlined above, your power cord is open. In other words, you will need to replace the power cable.

Teste ob ein Kabel unterbrochen ist, indem du eine der Messleitungen an einem Kontaktstift des Steckers, die andere in metallischen Kontakt mit der Buchse auf der Geräteseite bringst.

Wenn das Kabel leitet, piepst der Durchgangsprüfer fortwährend. Ein kurzes Piepen bedeutet noch nicht, dass das Kabel leitet. Wenn er nicht piepst, dann lege eine der Prüfspitzen am anderen Kontaktstift des Steckers an.

Ein Netzkabel hat ja zwei Adern, also musst du das Ganze für den andern Kontaktstift wiederholen.

Beide Adern müssen leitfähig sein, sonst ist dein Netzkabel defekt und du musst es austauschen.

crwdns2944171:0crwdnd2944171:0crwdnd2944171:0crwdnd2944171:0crwdne2944171:0