Testing Power Cord Continuity, Set the multimeter to continuity test mode: crwdns2935265:00crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Testing Power Cord Continuity, Set the multimeter to continuity test mode: crwdns2935265:00crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
Set the multimeter to continuity test mode
  • Unplug the power cord from the device and from the AC outlet. Failure to do so can result in electrical shock or death.

  • Set the multimeter to continuity test mode.

  • The setting is symbolized by a diode or sound wave symbol as seen in the pictures. If the meter is set to the correct mode, you should hear the meter beep when the leads are touched together.

  • Verify that the positive lead is plugged to the voltmeter/ ohmmeter outlet.

Ziehe den Netzstecker sowohl aus der Steckdose als auch aus dem entsprechenden Gerät. Alles andere könnte sehr gefährlich sein und sogar zu einem Stromschlag führen.

Stelle das Multimeter auf Durchgangsprüfung.

In den Bildern ist die Einstellung durch ein Dioden- oder Tonsymbol/Note gekennzeichnet. Das Multimeter piept, wenn man die Messleitungen verbindet.

Schaue nach, ob die Messleitungen richtig stecken, die schwarze in der mit COM, die rote mit Volt/Ohm bezeichneten Buchse.