crwdns2936071:01crwdne2936071:0 — Access to the thermostatic cartridge
WARNING: Before any intervention, make sure that the inverter is in the "OFF" position and close the water supply to the meter.
crwdns2936071:02crwdne2936071:0 — Dismantling the thermostatic handle
Before disassembling, check that the mark on the mixer tap is aligned with the "38°" position, then remove the handle.
crwdns2936071:03crwdne2936071:0 — Removing the thermostatic cartridge
Unscrew the thermostatic cartridge anti-clockwise using a 21 wrench.
crwdns2936071:04crwdne2936071:0 — Reassembly
Insert the thermostat in the mixer body.
crwdns2936071:05crwdne2936071:0 — Replacing and adjusting the stop ring
Position the two lines marked on the stop ring facing the point of the mixer tap.
crwdns2936071:06crwdne2936071:0 — Replacing the handle
Align the reference point on the mixer body with the 38° mark on the handle.