For single-pump models (Mighty Pro, X3), if the Rug Doctor does not spray at all, the pump requires replacement.
-
For the Wide Track model, if the Rug Doctor does not spray at all, both pumps require replacement.
-
If water splashes out of the nozzles for the Wide Track model but does not spray adequately, check the spray nozzles for clogs first.
-
If the nozzles are clear, one of the two pumps may be defective, not supplying sufficient pressure to the nozzles. If possible, replace both pumps.
-
If you need to determine which of the two pumps requires replacement, switch the Rug Doctor on to the upholstery mode. Do not disconnect the quick-connect for accessories. If water splashes out of the nozzles like the carpet mode, replace the front pump.
-
If water does not splash out of the nozzles in accessory mode, replace the rear pump.