Diagnosing and Erasing Hard Drives, Parted Magic - Reallocated sectors and SMART testing: crwdns2935265:00crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 Diagnosing and Erasing Hard Drives, Parted Magic - Reallocated sectors and SMART testing: crwdns2935265:00crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 Diagnosing and Erasing Hard Drives, Parted Magic - Reallocated sectors and SMART testing: crwdns2935265:00crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
Parted Magic - Reallocated sectors and SMART testing
  • If the Reallocated Sector Count is highlighted with a high count, REPLACE THE DRIVE; they are prone to failure and unexpected capacity loss! While SMART Extended is better, a quick test may be sufficient.

  • In the Attributes tab, locate the following SMART attributes: Reallocated Sector Count; Reallocation Event Count; Current Pending Sector Count.

  • To test the drive, select Perform Tests. Click Test type: and select Extended Self-Test.

Se la voce Reallocated Sector Count è evidenziata e il numero è elevato, sostituisci l'unità. Usa il test SMART esteso per una maggiore precisione. La capacità si ridurrà e spesso queste unità si guastano senza preavviso!

Nella scheda Attributes, individua i seguenti attributi SMART: Reallocated Sector Count; Reallocation Event Count; Current Pending Sector Count.

Per testare l'unità, seleziona la scheda Perform tests. Fai clic su Test type: e seleziona Extended Self-Test.

-[title] (Parted Magic) Check the reallocated sectors and test the drive
-[* icon_caution] ***''If Reallocated Sector Count is highlighted and the number is high, replace the drive. Use SMART Extended for accuracy. You will lose capacity and these drives often fail without warning!''***
+[title] Parted Magic - Reallocated sectors and SMART testing
+[* icon_caution] ***If the Reallocated Sector Count is highlighted with a high count, REPLACE THE DRIVE; they are prone to failure and unexpected capacity loss!*** While SMART Extended is better, a quick test may be sufficient.
[* orange] In the ***''Attributes''*** tab, locate the following SMART attributes: ***''Reallocated Sector Count; Reallocation Event Count; Current Pending Sector Count''***.
[* yellow] To test the drive, select ***''Perform Tests''***. Click ***''Test type:''*** and select ***''Extended Self-Test''***.

crwdns2944171:0crwdnd2944171:0crwdnd2944171:0crwdnd2944171:0crwdne2944171:0