Repairing Quasar Microwave Sparking Inside

crwdns2936025:02crwdne2936025:0 —

crwdns2935477:0crwdne2935477:0:

crwdns2935483:0crwdne2935483:0

If the microwave continues to spark after the interior has been cleaned, that could indicate that the diode may be broken. The diode is what attaches the capacitor to the back of the microwave.

A multimeter can be used to measure the resistance of the diode. The multimeter must be on the resistance setting or the diode check setting. If the diode reads zero in both directions, then it is broken.