[* black] Draw 5 ml of fluid into the second RockShox bleed syringe. Hold the syringe upright, cover the tip with a shop towel, and gently depress the plunger to purge any air bubbles from the syringe. | |
+ | [* black] Remove the bleed screw at the seat post and thread the standard syringe bleed fitting into the seat post bleed port. |
[* black] Depress the remote syringe plunger while pulling the seatpost syringe plunger out. | |
[* icon_caution] Do not empty the syringe. Leave at least 5 ml of fluid in each syringe during the procedure to avoid air entering the system. | |
[* black] Depress the seatpost syringe plunger while pulling the remote syringe plunger out. Repeat these steps until bubbles are no longer pulled from the remote and seatpost. |