- | [* black] Draw 5 mL of fluid into the second RockShox bleed syringe. Hold the syringe upright, cover the tip with a shop towel, and gently depress the plunger to purge any air bubbles from the syringe. |
---|---|
- | [* black] Depress the remote syringe plunger while pulling the seatpost syringe plunger out. ***Do not empty the syringe. Leave at least 5 mL of fluid in each syringe during the procedure to avoid air entering the system.*** |
- | [* black] Depress now the seatpost syringe plunger while pulling the remote syringe plunger out. Repeat these steps until bubbles are no longer pulled from the remote and seatpost. |
+ | [* black] Draw 5 ml of fluid into the second RockShox bleed syringe. Hold the syringe upright, cover the tip with a shop towel, and gently depress the plunger to purge any air bubbles from the syringe. |
+ | [* black] Depress the remote syringe plunger while pulling the seatpost syringe plunger out. |
+ | [* icon_caution] Do not empty the syringe. Leave at least 5 ml of fluid in each syringe during the procedure to avoid air entering the system. |
+ | [* black] Depress the seatpost syringe plunger while pulling the remote syringe plunger out. Repeat these steps until bubbles are no longer pulled from the remote and seatpost. |