Note that from the Power Input module X12 and X16 go the the water valve board #4. Since everything else comes off bd #1, that is a big clue. If you replaced all the boards, then either there is something wrong with bd #1, #2, or #3, or there is an open circuit in one of the connecting cables.
Bd #2 is likely an AC to DC module. So, X200 & X300 will probably have DC voltages on them. X100 will have AC voltage on it. That will shut down everything except the water valve if it is bad. That would be my 1st suspect. See if you can measure any DC voltages on X301 or X201. If no, find out why, cable or bd #2. If no AC input, then bd #3. Because of the proximity of X10 and X301, I would guess that X301 is supplying 12VDC thru X10 to bd #4. So I would concentrate on X201 voltages.
I don't think there will be a single point failure on bd #1 that will cause your symptoms.
crwdns2934105:0crwdne2934105:0
crwdns2934113:0crwdne2934113:0
crwdns2915270:0crwdne2915270:0
crwdns2889612:0crwdne2889612:0
0
crwdns2944067:05crwdne2944067:0
be nice to have a schematic. Generally those are hiden somplace undet or behind most fridges
crwdns2934271:0crwdnd2934271:0 bill crwdne2934271:0
I have the schematic unfortunately it does not show the voltages in and out of the boards
crwdns2934271:0crwdnd2934271:0 clive chotalal crwdne2934271:0
Were you able to resolve your problem? My Bosch 800 Series Refrigerator is having the same issue, but it started with the water dispenser not working. I replaced the valve and it worked for a day before the Main Display shutdown, but the water dispenser still works. I have a Control Board on order as my last hope for repairing my self.
crwdns2934271:0crwdnd2934271:0 Marc Mumbleau crwdne2934271:0
I was not able to get it fixed I changed all 3 major boards and still no luck
crwdns2934271:0crwdnd2934271:0 clive chotalal crwdne2934271:0
How did you get the boards out to replace them? I'm not seeing how they come out.
crwdns2934271:0crwdnd2934271:0 Marc Mumbleau crwdne2934271:0