Test the element with a multimeter
-
Set the multimeter to measure resistance in ohms.
-
Place one lead on each element terminal and wait for a stable reading.
-
Confirm a typical reading between 20 and 40 ohms to show a healthy element.
-
Reinstall the element with the mounting screws and reconnect any wires securely.