Whirlpool Dryer Heating Element Testing and Replacement, Heater continuity check and ground check: crwdns2935265:00crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Whirlpool Dryer Heating Element Testing and Replacement, Heater continuity check and ground check: crwdns2935265:00crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
Heater continuity check and ground check
  • (For three terminal heaters only) Check the resistance between the top and bottom terminals.

  • The multimeter should read about 40–50 Ω.

  • (All types) Check resistance from the each terminal to the heater housing.

  • The multimeter should read OL or "—"

  • If the element has the correct values when tested, you can stop here. You don't have to replace the heating element. As a precaution, while everything is accessible, you may want to test the components located on the heater housing.

  • For the hi limit thermostat/inlet thermistor combined component follow this link.

  • For the thermal cutoff switch, follow this link