crwdns2933423:0crwdne2933423:0

Reemplazo y prueba de la resistencia en una secadora Whirlpool

crwdns2936315:0crwdne2936315:0
crwdns2936331:0crwdne2936331:0
crwdns2931653:04crwdne2931653:0
Whirlpool Dryer Heating Element Testing and Replacement, Heater continuity check and ground check: crwdns2935265:00crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Whirlpool Dryer Heating Element Testing and Replacement, Heater continuity check and ground check: crwdns2935265:00crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
Heater continuity check and ground check
  • (For three terminal heaters only) Check the resistance between the top and bottom terminals.

  • The multimeter should read about 40–50 Ω.

  • (All types) Check resistance from the each terminal to the heater housing.

  • The multimeter should read OL or "—"

  • If the element has the correct values when tested, you can stop here. You don't have to replace the heating element. As a precaution, while everything is accessible, you may want to test the components located on the heater housing.

  • For the hi limit thermostat/inlet thermistor combined component follow this link.

  • For the thermal cutoff switch, follow this link

(Sólo para calentadores de tres terminales) Comprueba la resistencia entre los terminales superior e inferior.

El multímetro debe indicar unos 40-50 Ω.

(Todos los tipos) Comprueba la resistencia entre cada terminal y la carcasa del calentador.

El multímetro debe indicar OL o "-".

Si el elemento tiene los valores correctos al comprobarlo, puedes parar aquí. No tienes que sustituir el elemento calefactor. Como precaución, mientras todo esté accesible, puedes probar los componentes situados en la carcasa del calentador.

Para el componente combinado termostato de alto límite/termistor de entrada, sigue este enlace.

Para el interruptor de corte térmico, sigue este enlace

crwdns2944171:0crwdnd2944171:0crwdnd2944171:0crwdnd2944171:0crwdne2944171:0