How to Fix a Solder Bridge: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
  • Verify the circuit board does not have any current supplied to it prior to performing the next steps. If a current is present, permanent damage to the multimeter is possible!

  • Connect the black probe to the circuit board rail where one end of the solder bridge was.

  • Connect the red probe to the circuit board rail where the other end of the solder bridge was.

  • If the fix is successful, the multimeter should read "OL" on the screen, indicating an open circuit. There should be no beep, which means the rails are no longer connected.

  • If the fix was unsuccessful, the multimeter will give a numerical readout on the multimeter screen, and beep.

注意:在进行通断测试时请勿给电路板加电,带电测试可能会导致万用表永久性损坏。

用黑表笔碰触原桥接点的一端。

用红表笔碰触另一端。

若万用表显示“OL”且无声,则证明原桥接点已无连通,修复成功。

若万用表显示数值并发出蜂鸣,则代表仍有短接点,需要再次修复。