How to test a GFCI/RCD, Apply a load between L and PE: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
Apply a load between L and PE
  • Use the load feature of the Duspol to apply a load between L and PE.

  • This will not trigger an RCD with a rated residual current higher than 30 mA, though you shouldn't have an RCD rated over 30 mA installed in your home, as that's the maximum permissible rated residual current for personal protection anyways.

  • If your Duspol does not have the load feature or if you do not have a Duspol, you can still test the GFCI by shorting the neutral to ground. However, to do this, it is important to ensure that a device is currently drawing power from the circuit being tested. This is typically the case in most household settings.

Verwende die Lastfunktion des Duspols, um eine Last zwischen L und PE anzulegen.

Ein RCD mit einem Auslösestrom höher als 30 mA wird dadurch nicht ausgelöst. Du solltest auch keinen RCD mit einem höheren Auslösestrom als 30 mA im Haus installiert haben, das ist die maximal erlaubte Schwelle zum Schutz von Personen.

Wenn dein Duspol keine Lastfunktion hat oder du keinen Duspol hast, kannst du den RCD trotzdem testen, indem du den Neutralleiter mit dem Schutzleiter kurzschließt. Es ist jedoch wichtig sicherzustellen, dass ein Gerät derzeit Strom aus dem zu testenden Stromkreis zieht. Dies ist in der Regel in den meisten Haushaltseinstellungen der Fall.