  • Reinstall the light pull-switch into the circuit.

  • Terminate the hot and neutral wires with the appropriate wire bundle using twist-on wire connectors.

  • After the completion of this step, there should be 4 white wires connected bound with one twist-on wire connector, and 2 black wires bound using a second twist-on wire connector.

  • Wire color-coding in accordance with the NFPA 70 - National Electrical Code is applicable. White wires are designated as neutral wires, black wires are designated as hot wires.

Reinstala el interruptor de luz en el circuito.

Conecta los cables de fase y neutro con el mazo de cables correspondiente mediante conectores de torsión.

Después de completar este paso, debe haber 4 cables blancos conectados con un conector de torsión y 2 cables negros conectados con un segundo conector de torsión.

Se aplica la codificación por colores de los cables según la norma NFPA 70 (Código Eléctrico Nacional). Los cables blancos se designan como neutros y los cables negros, como cables de fase.