GeneralAire GA50A20 APS and PCB Replacement

crwdns2935425:08crwdne2935425:0

crwdns2936315:0crwdne2936315:0
crwdns2936317:0crwdne2936317:0
crwdns2931653:08crwdne2931653:0
crwdns2933707:0crwdne2933707:0
Final Testing
  • Reverse the order of testing:

  • Connect the air proving switch and verify voltage at pins 1 & 4.

  • Connect the transformer and verify 24VAC out when energized and the air proving switch is cold.

  • DO NOT USE OR MEASURE THE HIGH VOLTAGE BOARD WITH ANYTHING OTHER THAN NON CONTACT VOLTAGE PROBE.

  • With everything connected, powered up the unit and watched the indicator come on and go off. I turned on the fan to the air unit and the indicator came back on and very carefully bringing the voltage probe near the HV lines, I got some nice chirping.