TM3D DWIN Added Screens

crwdns2936315:0crwdne2936315:0
crwdns2936325:0crwdne2936325:0
crwdns2931653:02crwdne2931653:0
TM3D DWIN Added Screens, Calibration Screens: crwdns2935265:00crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 TM3D DWIN Added Screens, Calibration Screens: crwdns2935265:00crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
Calibration Screens
  • These values are set for your machine and normally do not need modified. Edit at your own risk! However, if you feel you make a mistake, you can Initialize EEPROM from the Tools menu.

  • Calibration

  • The white boxes will all be populated with your printer's settings.

  • Probe Offset can be changed if you change the probe to nozzle relationship.

  • Steps/mm can be changed to fine tune your machine or add an aftermarket extruder. A popular bench test is a 20mm cube.

  • Calibration-PID Tuning>PID Automatic Tuning will initiate an automatic PID calibration. Enter a temperature 10 degrees over your printing temperature and press Start.

  • Calibration-PID Tuning>PID Manual Tuning will display the current saved values and allow manual adjustment.

  • After desired changes are made, press Store Settings