MacBook Pro 13" Unibody Mid 2009 Optical Drive Replacement: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
  • It will be necessary to slide the small clear plastic cable retainer (boxed in red) glued to the logic board out of the way before disconnecting the camera cable. Be careful not to break any components off the board as you slide it away from the camera cable connector.

  • Pull the camera cable connector toward the optical drive to disconnect it from the logic board.

  • This socket is metal and easily bent. Be sure to align the connector with its socket on the logic board before mating the two pieces.

È necessario spingere via il piccolo fermacavi in plastica (evidenziato in rosso) incollato alla scheda logica prima di scollegare il cavo della fotocamera. Stai attento a non rompere alcun componente della scheda mentre lo allontani dal connettore del cavo della fotocamera.

Tira il connettore del cavo della fotocamera in direzione dell'unità ottica per scollegarlo dalla scheda logica.

Questa presa è in metallo e si piega facilmente. Assicurati che il connettore e la presa sulla scheda logica siano ben allineati prima di accoppiare i due pezzi.