Gamma Scout Geiger Counter Battery Replacement, Opening the case: crwdns2935265:00crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
Opening the case
  • After you have removed all the three screws, the case should easily come apart.

  • For this step you will not need any tools, because the front and back parts of the case will get apart easily.

  • Notice that the PCB will remain attached to the front side of the case, so it is recommended to lift up the back side of the case while holding the device upside-down.

  • Make sure not to touch the upper part of the PCB or the geiger tube, because these parts of the device are under high voltage.

  • Be careful not to hit or touch the front end window of the geiger tube, because it is made out of a very thin and very fragile material.

Nachdem Sie die drei Schrauben entfernt haben, sollte das Gehäuse leicht auseinanderkommen.

Für diesen Schritt brauchen Sie keine Werkzeuge, da sich die Vorderseite und die Rückseite des Gehäuses leicht voneinander lösen lassen.

Beachten Sie, dass die Platine weiterhin an die Vorderseite des Gehäuses befestigt ist, also es wird empfohlen die Rückseite des Gehäuses anzuheben, während Sie Ihr Gerät mit der Vorderseite nach unten halten.

Bitte achten Sie darauf, den oberen Teil der Platine oder das Zählrohr nicht zu berühren, weil diese Teile des Gerätes unter Hochspannung stehen.

Bitte achten Sie darauf, die Vorderseite des Zählrohrs nicht zu berühren oder anzustoßen, da es aus einem sehr dünnen und sehr zerbrechlichen Material ist.