Bodum Bistro B.Over Coffeemaker Thermal Cutoff Fuse Replacement, Symptoms - Before getting started.: crwdns2935265:00crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 Bodum Bistro B.Over Coffeemaker Thermal Cutoff Fuse Replacement, Symptoms - Before getting started.: crwdns2935265:00crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 Bodum Bistro B.Over Coffeemaker Thermal Cutoff Fuse Replacement, Symptoms - Before getting started.: crwdns2935265:00crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
Symptoms - Before getting started.
  • Power LED on, water level not dropping or stopped dropping on brewing.

  • After opening the base cover, you can check the thermal cutoff fuse by measuring resistance between Neutral - the white wire from power plug and the contact at lower of water heater (which is behind the metal plate below the water heater connecting to Ground - green wire)

  • If the resistance level is indefinite (cutoff), this mean you have a brown fuse.

  • If Power LED cannot turn on, you might have problem with one of microswitch, water level sensor and jug position sensor. In this case, you might try to clean the microswitch with electronic contact cleaner.

電源燈號有亮,但是沒有開始煮,或是煮到一半水位停止下降。

打開底座後,可以先嘗試測量電源的白色中性線跟加熱器下方的接頭之間的電阻,如果溫度保險絲燒掉,這兩個點會呈現斷路。加熱器的接頭在接地的鐵板後方,要技巧性的繞過去量。

如果電源燈無法打開,最有可能的是其中一個微動開關故障。共有兩個微動開關,一個用來偵測水位,另外一個是確定壺有在座上。微動開關故障可以嘗試用接點清潔劑噴了後,按壓開關清潔看看。