[* black] Make sure the machine is turned off and unplugged. | |
[* black] Set your voltmeter in continuity mode and place the leads on the two 90 degree prongs on the boiler's heating element. | |
- | |
+ | [* icon_note] It does not matter which lead touches which prong as you're just testing for a break, or "open" in the heating element circuit.''' |
[* black] If the voltmeter shows 0, or "open", then there is an issue with the heating element's continuity and it needs to be replaced. | |
[* black] If given a reading, then your heating element is fine. |