+[title] Examine and test the thermostats and fuses
+[* black] [youtubetimestamp|683.2|803.4]Set the multimeter to ohms or continuity when testing each thermostat or safety fuse.
+[* black] Remove at least one wire from each thermostat or fuse to prevent false readings.
+[* black] Verify each large terminal shows near 0.00 ohms or a beep of continuity if in working condition.
+[* black] Check small terminals for around 9000 ohms on sensor style thermostats, replacing them if values are off.
+[* black] Replace any component that reads open line (OL) or has abnormal readings.