+ | [title] Examine and test the thermostats and fuses |
---|---|
+ | [* black] [youtubetimestamp|683.2|803.4]Set the multimeter to ohms or continuity when testing each thermostat or safety fuse. |
+ | [* black] Remove at least one wire from each thermostat or fuse to prevent false readings. |
+ | [* black] Verify each large terminal shows near 0.00 ohms or a beep of continuity if in working condition. |
+ | [* black] Check small terminals for around 9000 ohms on sensor style thermostats, replacing them if values are off. |
+ | [* black] Replace any component that reads open line (OL) or has abnormal readings. |