[title] Inspect power connections
-[* black] [youtubetimestamp|81.8|114.7]Move the dryer to access the rear panel where the power cord enters.
-[* black] Remove the lower panel screw with a quarter inch hex head driver and open the panel.
-[* black] Look for any signs of damage or burnt wiring on the terminal block or cord.
-[* black] Use a multimeter set to AC voltage to confirm 120 volts on each leg to neutral and about 208 to 240 volts across both hot legs.
-[* black] Reset the breaker if voltage is incorrect, or replace the cord or consult an electrician if the outlet is faulty.
+[* black] [youtubetimestamp|81|115]Move the dryer to access the rear panel where the power cord enters.
+[* black] [youtubetimestamp|81|115]Remove the lower panel screw with a quarter inch hex head driver and open the panel.
+[* black] [youtubetimestamp|81|115]Look for any signs of damage or burnt wiring on the terminal block or cord.
+[* black] [youtubetimestamp|81|115]Use a multimeter set to AC voltage to confirm 120 volts on each leg to neutral and about 208 to 240 volts across both hot legs.
+[* black] [youtubetimestamp|81|115]Reset the breaker by turning it off, then cycling on, if voltage is incorrect, or replace the cord or consult an electrician if the outlet is faulty.