- | [* black] Check that the |
---|---|
- | [* black] Further details can be found in the 'RXE100 service manual' widely available for free on-line. |
+ | [* black] Check that the idling current between the arrowed test points (of the same colour) is 0.1-15mV at start-up or 0.25-15mV after 1 hour for both resistors. Mine was a satisfactory 0.9mV. |
+ | [* black] Further details can be found on page 8 in the 'RXE100 service manual' widely available for free on-line. |