+[title] Unfasten the MagSafe port
+[* red] Use a T2 Torx driver to ***loosen*** the two set screws in the frame that align the MagSafe port.
+ [* icon_note] Don't remove these screws. Just loosen them a few turns above the frame.
+[* orange] Use your Torx Plus 5IP driver to remove the two 2.7 mm-long screws securing the MagSafe port.
+ [* icon_note] These screws are non-magnetic, so be careful not to lose them.