+ | [title] Test the flap door motor |
---|---|
+ | [* icon_note] If you have a multimeter, you can test to see if your flap door motor is good or not. |
+ | [* icon_note] Set your multimeter to the resistance function. |
+ | [* black] Touch one probe to each of the terminals at the same time. |
+ | [* icon_note] The meter should read between 9 and 14Ω. |
+ | [* icon_note] If the reading is outside of this range, replace the flap door motor. |