+[title] Test the inlet valve assembly
[* icon_note] If you have a multimeter, you can use it to test the inlet valve assembly components.
[* icon_note] Set the multimeter to the ohm (Ω) setting.
[* black] For the first solenoid, test the resistance between the red and blue wires on the white connector.
[* icon_note] The acceptable resistance is 360 to 420 Ω.
[* black] Repeat the test on the yellow connector for the other solenoid.
[* icon_note] The acceptable resistance is 360 to 420 Ω.
[* black] To test the flow meter, test the resistance between the red and black wires on the white connector.
[* icon_note] The acceptable resistance is 4 kΩ to 30 kΩ.