+[title] Test the main winding
+[* icon_note] This step will require a multimeter. If you aren't familiar with how to use one, [guide|25632|here is a guide|new_window=true] that will help you.
+[* black] Disconnect the top bare copper wire aligned with terminal #5.
+[* icon_caution] Be sure to grip the connector and not the wire when disconnecting.
+[* black] Measure the resistance from the diagonal terminal (between terminals #4–#6) and the top copper wire aligned with terminal #5.
+[* black] This reading should be 3.3–3.6 Ω. If it is outside this range the motor is defective and should be replaced.