+ | [title] Test the start winding |
---|---|
+ | [* icon_note] This step will require a multimeter. If you aren't familiar with how to use one, [guide|25632|here is a guide|new_window=true] that will help you. |
+ | [* black] You will need the wiring schematic for your dryer to figure out what terminals are for the start winding. Usually one of those terminals will be shared with the run winding. |
+ | [* black] Measure the resistance from the start winding to the common terminal shared between the start and run windings. Use the lowest resistance setting (usually Rx1) on your multimeter if you need to set it manually. |
+ | [* icon_note] The value should be 2–5 Ω. If it's outside that range or OL, the motor is defective and needs to be replaced. The picture shows a good value. |