+[title] Test the start winding
+[* icon_note] This step will require a multimeter. If you aren't familiar with how to use one, [guide|25632|here is a guide|new_window=true] that will help you.
+[* black] Disconnect the lower bare copper wire aligned with terminal #3.
+[* black] Measure the resistance from the diagonal terminal (between terminals #4–#6) and the wire removed aligned with terminal #3.
+[* icon_note] The value should be 2.7–3.0 Ω. If it's outside that range or OL, the motor is defective and needs to be replaced. The picture shows a good value.