[title] Test the inlet thermistor
[* icon_note] If you just need to replace the hi-limit thermostat or inlet thermistor, you can skip this step.
[* yellow] With the thermistor removed from the heater housing, test for resistance with the multimeter across the two small terminals.
-[* black] The value shown (61.8 kΩ) is acceptable for a good thermistor at room temperature (68°F/20°C). The nominal range at this temperature is 61.2‑63.7 kΩ.
-[* black] If the device shows outside this range, replace it.
+[* black] The resistance values of this component vary. You may be able to locate a tech sheet booklet in the chassis of the dryer to find the value.
+[* black] If the device shows outside the correct range, replace it.