-[title] Heater through check and ground check
+[title] Heater continuity check and ground check
[* black] (For three terminal heaters only) Check the resistance between the top and bottom terminals.
[* icon_note] The multimeter should read about 40–50 Ω.
-[* black] Check resistance from the each terminal to the heater housing.
+[* black] (All types) Check resistance from the each terminal to the heater housing.
[* icon_note] The multimeter should read OL or "—"
[* black] If the element has the correct values when tested, you can stop here, you don't have to replace the it.