+ | [title] Testing the switch |
---|---|
+ | [* icon_note] This step will require a multimeter. If you aren't familiar with how to use one, [guide|25632|here is a guide|new_window=true] that will help you. |
+ | [* black] Insert the multimeter's probes into the two outermost sockets on the switch connector and test continuity and open on the door switch. |
+ | [* icon_note] When the button on the switch is not pushed, the meter should indicate ***''OL''***. |
+ | [* icon_note] When the button is pushed with the probes in the same place, the meter should read less than 1 Ω. |
+ | [* black] If either of these readings is wrong, especially with the button pressed, replace the switch. |