[title] Test the main winding | |
[* icon_note] This step will require a multimeter. If you aren't familiar with how to use one, [guide|25632|here is a guide|new_window=true] that will help you. | |
[* black] Disconnect the bare copper wire in line with pin 5 (the upper terminal with a bare copper wire). | |
- | [* icon_caution] Be sure to grip the |
+ | [* icon_caution] Be sure to grip the connector and not the wire when disconnecting. |
[* black] Measure the resistance between the diagonal terminal that you used in the prior step and the connector on the bare copper wire. | |
[* black] This reading should be between 3.3 and 3.6 Ω. If it is outside this range the motor is defective and should be replaced. |