crwdns2933423:0crwdne2933423:0

crwdns2933803:07crwdne2933803:0

crwdns2933797:0Bill Gilbertcrwdnd2933797:0crwdne2933797:0

crwdns2936043:0crwdne2936043:0 crwdns2933505:0crwdne2933505:0 Bill Gilbert

crwdns2933769:0crwdne2933769:0
crwdns2933771:0crwdne2933771:0
crwdns2933801:0crwdne2933801:0

crwdns2933807:0crwdne2933807:0

[title] Test the inlet thermistor
-[* icon_note] If you just need to replace the hi-limit thermostat or inlet thermistor, you can skip this step.
+[* icon_note] This step shows how to test the inlet thermistor. If you just need to replace the hi-limit thermostat or inlet thermistor, you can skip this step.
[* yellow] With the thermistor removed from the heater housing, test for resistance with the multimeter across the two small terminals.
-[* black] The value shown (61.8 kΩ) is acceptable for a good thermistor at room temperature (68°F/20°C). The nominal range at this temperature is 61.2‑63.7 kΩ.
+[* icon_note] The value shown (61.8 kΩ) is acceptable for a good thermistor at room temperature (68°F/20°C). The nominal range at this temperature is 61.2‑63.7 kΩ.
[* black] If the device shows outside this range, replace it.