[title] Test the inlet thermistor | |
+ | [* icon_note] If you just need to replace the hi-limit thermostat or inlet thermistor, you can skip this step. |
[* yellow] With the thermistor removed from the heater housing, test for resistance with the multimeter across the two small terminals inside the yellow circle. | |
[* black] The value shown (61.8kΩ) is acceptable for a good thermistor at room temperature (68°F/20°C). The nominal range at this temperature is 61.2-63.7kΩ. | |
[* black] If the device shows outside this range, replace it. |