[* black] Check the resistance between the top and bottom terminals.
[* icon_note] The multimeter should read about 40 Ω.
[* black] Check resistance from the middle terminal to the heater housing.
[* icon_note] The multimeter should read OL or "—"
-[* black] If the element has the correct values when tested, you can stop here, you don't have to replace the it.
+[* icon_note] If the element has the correct values when tested, you can stop here. You don't have to replace the heating element. As a precaution, while everything is accessible, you may want to test the components located on the heater housing.
+ [* icon_note] For the hi limit thermostat/inlet thermistor combined component follow [guide|160810|this link|stepid=338675|new_window=true]
+ [* icon_note] For the thermal cutoff switch follow [guide|160818|this link|stepid=338706|new_window=true].