crwdns2933803:04crwdne2933803:0
crwdns2933797:0Alex Diaz-Kokaislcrwdnd2933797:0crwdne2933797:0
crwdns2936043:0crwdne2936043:0 crwdns2933505:0crwdne2933505:0 Alex Diaz-Kokaisl
- crwdns2933769:0crwdne2933769:0
- crwdns2933771:0crwdne2933771:0
- crwdns2933801:0crwdne2933801:0
crwdns2933807:0crwdne2933807:0
- | [* black] When you meter from section to section it should be about 40 Ω. |
---|---|
- | [* black] You should also check to see if the element has a short to ground. |
- | [* black] Check resistance from the common terminal to the heater housing. it should read OL or --- |
- | [* black] If the element has the correct values when tested, you can stop here, the heating element is good. |
+ | [* black] Check the resistance between the top and bottom terminals. |
+ | [* icon_note] The multimeter should rear about 40 Ω. |
+ | [* black] Check resistance from the middle terminal to the heater housing. |
+ | [* icon_note] The multimeter should read OL or "—" |
+ | [* black] If the element has the correct values when tested, you can stop here, you don't have to replace the it. |